View and Download Digitax F1 plus user manual online. F1 plus automobile accessories pdf manual download. Digitax f2 taximeter user manual Digitax f2 taximeter user manual I thought DP8. Any suggestion guyz Thanks advance in HSIC ECN as of May 21, 2012 1 Understand the Oracle Portal Components Device Driver atapi - DriverStartIo Device Ide IdePort0 872032C6 O9 - Extra button Upromise TurboSaver- 06E58E5E-F8CB-4049-991E-A41C03BD419E - C Program Files. The Digitax F1 Taximeter has several communication channels that make possible the communication with the external world. Two independent RS232 serial ports at baud rate from 300 to 115200 and a 4 wire synchro channel plus a special printer driver, allow. The f1 is similar to the f2 version but has a higher specification. MODEL IS THE F1 PLUS. Digitax RTC taxi meter - this is the F1 Plus - higher spec than the cheaper F2 eBay. Digitax ST is quick and easy to set-up. The drives may be configured using the removable keypad, SmartCard or the supplied commissioning software to guide the user through the configuration process. Auto-tune features help you to get the best performance by measuring the machine dynamics and automatically optimizing the control loop gains.
- Digitax F1 User Guide Download
- Digitax F1 User Manual
- Digitax F1 User Guide Pdf
- Digitax F1 User Guide Manual
Taximeter F2 Standard F2 RTC
The Digitax taximeter has five keys: OP, K1, K2, K3, K4
The taximeter has three working modes: For Hire, Hired and Stopped.
The taximeter’s working modes are selectable by pressing the OP button in the following sequence:
OP
In any of the the above taximeter’s working modes (FOR HIRE, HIRED, STOPPED), the other four keys K1, K2, K3, K4 will exploit a different function, as described below:
Taxi in “FOR HIRE” When the Taxi is parked or it moves without any passengers, the driver selects the For Hire position. Once the taxi starts the trip, the taxi driver selects the Hired position using the OP key. | K3 – Shows Date and Clock (RTC Only) K4 – Shows Year (RTC Only) OP – Selects Hired |
Taxi in “HIRED” The “Taxi” roof sign will turn off and the taximeter starts the fare calculation by distance or time. At the end of the trip, the taxi driver has to select the Stopped position using the OP key. | K1 – Next Tariff (if enabled) OP – Selects Stopped |
Taxi in “STOPPED” other extras to the fare (if enabled). The taxi driver then presses OP to return to For Hire. | K1 – Insert Special Extras (if enabled) K2 – Insert Extra No.3 (if enabled) OP – Selects For Hire |
Turning the Meter Off
On the 32 Block F2 and F2 RTC meters the meter can be turned off by pressing the K2 and K4 buttons at the same time. The only exception to this is on the 4 Block F2 where the K1 button will turn the meter off.
The meter can be turned on again by pressing the OP button.
Select For Hire position.
Press K1 and K3 together.
The signs “FOR HIRE” and “STOPPED” are lit up.
The big display shows the Day number on the left, and the Month number on on the right.
The small display shows the Time in Hours and Minutes.
Digitax F1 User Guide Download
Press K1 to set the Day number.
Press K2 to set the Month number.
Press K3 to set the Hour number (24 hour clock). Press K4 to set the Minute number.
Press OP to set the Year.
Press K1 to increase the Year number. Press K2 to decrease the Year number.
Please Note: The ability to set the time and date may have been disabled depending on the setup of the meter.
How to Convert the Local Currency into Euros and Vice Versa
(if enabled)
In Hired and Stopped modes press the K3 key to toggle from the local currency to Euros and vice versa.
Digitax F1 User Manual
Memory Functions
The taximeter records and keeps data in 2 memory blocks, each divided into 7 sections. Block 1 can be read and erased freely, Block 2 can only be read. The memory sections correspond to:
Digitax F1 User Guide Pdf
Index 1 – Total Number of Trips
Index 2 – Total Units
Index 3 – Total Miles in Hired/Stopped Index 4 – Total Miles
Index 5 – Hours in Waiting Time
Index 6 – Income by the Fare
Index 7 – Income by the Extras
- Select the For Hire position.
- Press K2 and K1 together
- The “FOR HIRE” sign will start blinking and the extras display will show the memoryindex.
- K2 increases the index number.
- K1 decreases the index number.
- K3 toggle between Block 1 and Block 2.
- Press OP to end the memory reading and return to For Hire.How to Print the Memory Content(if a printer is attached)
- Select the For Hire position.
- Press K2 and K1 together
- The “FOR HIRE” sign will start blinking and the extras display will show the memoryindex.
- Reach the memory index 5 by pressing the K2 key.
- Reaching location 5, press the K4 key to print out the content of both Block 1 and Block2. The “FOR HIRE” sign will stop blinking and the printer will start.
- Press OP to end the printing procedure and go back to the For Hire position.How to Erase the Memory Content
- Select the For Hire position.
- Press K2 and K1 together
- The “For Hire” sign will start blinking .
- Reach the memory index 6 by pressing the K2 button
- Press K4. This will erase Block 1’s content and, if a printer is attached, will print outMemory Block 1 and 2.
Digitax F1 User Guide Manual
- User Guides
If you require a different user guide relating to Digitax HD M751 Base, Option Module User Guides, Issue Guides, Installation Sheets, EMC Drawings, CMD/XML Files, GSD/GSDML Files, EDS Files, Application Notes, Software & Firmware Archive, please click here.
Basic User Guides
What you'll find:
- Digitax HD M75X Quick Start Guide
Advanced User Guides
What you'll find:
- Digitax HD M75X Installation and Technical Guides
- Digitax HD M751 Control User Guide
- Digitax HD M751 Parameter Reference Guide
- Software
Connect
Drive configuration tool for commissioning, optimizing and monitoring drive/system performance.
Machine Control Studio
A flexible and intuitive environment for programming Digitax HD's new automation and motion control features.
- Support
Contact Control Techniques
If you're unable to download the diagnostics tool, our global support team can help. You can find your local Automation Center or Distributor or submit a question through our enquiry form.
Diagnostic App
Diagnostic Tool is a fast and simple tool, which allows users of Control Techniques' drives to quickly solve any error codes that the drive may show. Built within the app are easy to locate wiring diagrams for first time setup and fault finding with links to the relevant comprehensive manuals.
- Digitax HD M751 Base Options
KI Compact Display
The display (fitted on M753, optional on M751) ensures access to drive diagnostics even in the absence of network connectivity. Includes 2 rotary switches for hardware setting of the node address for faster commissioning of the motion network.
Remote Keypad RTC
The keypad is remote mountable, allowing flexible mounting on the outside of a panel (meets IP54/NEMA 12). Three line plain text, multi-language LCD keypad for rapid set-up and helpful diagnostics. Battery operated real-time clock allows accurate time stamping of events, aiding diagnostics.
KI-Compact 485 Adaptor
This allows the drive to communicate via RS485. This is commonly used for programming if a keypad or KI Compact Display is not ordered with the drive.
ORDER CODE: 82700000020300
CT USB Communications Cable
The USB Communications cable allows the drive to connect to a PC for use with PC tools*.
ORDER CODE: 82500000018500
* Also requires KI-Compact-485 Adaptor.
SI-Encoder
Quadrature encoder input interface module.
ORDER CODE: 82400000018100
SI-Universal Encoder
Encoder input and output interface supporting Quadrature, SinCos, EnDat and SSI encoders.
ORDER CODE: 82400000018300
SI-DeviceNet
SI-DeviceNet enables follower connectivity. It is possible to use multiple SI-DeviceNet modules to provide additional functionality.
ORDER CODE: 82400000017700
SI-PROFIBUS
It is possible to use multiple SI-PROFIBUS modules or a combination of SI-PROFIBUS and other option module types to add additional functionality such as extended I/O, gateway functionality or additional PLC features.
ORDER CODE: 82400000017500
SI-CANopen
Digitax HD’s CANopen interface module supports various profiles, offering optimum flexibility.
ORDER CODE: 82400000017600
SI-Ethernet
SI-Ethernet can be used to provide high speed drive access, global connectivity and integration with IT network technologies.
ORDER CODE: 82400000017900
SI-EtherCAT
SI-EtherCAT allows Digitax HD servo drives to connect and interface with EtherCAT networks.
ORDER CODE: 82400000018000
SI-PROFINET
SI-PROFINET allows Digitax HD to communicate and interface with PROFINET PLCs and networks.
ORDER CODE: 82500000018200
SI-I/O
Extended I/O interface module increases the number of I/O points on a drive.
ORDER CODE: 82400000017800
SI-Apps Compact
Compatible module allows SyPTPro application programs to be re-complied for HD.
ORDER CODE: 82400000020700
MCi200
Second processor, providing advanced customization using industry standard IEC61131-3 programming languages.
ORDER CODE: 82400000017000
MCi210
Extended advanced machine control, provides MCi200 functionality with additional ports and simultaneous connectivity to 2 separate Ethernet networks.
ORDER CODE: 82400000016700